Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
GEN ; 61(4): 256-258, dic. 2007. ilus, tab
Article in Spanish | LILACS | ID: lil-664293

ABSTRACT

Introducción: la gran demanda de un método confiable, reproducible, específico y altamente sensible para la cuantificación de ácidos nucleicos (ADN/ ARN), marcó el desarrollo de los ensayos de Reacción en Cadena de la Polimerasa cuantitativa (RCPc) en tiempo real. Objetivo: descripción y análisis de la RCPc en tiempo real para la definición y el manejo actual de los pacientes con hepatitis crónica B (HCB). Material y Método: fueron investigadas cuarenta muestras de suero provenientes de portadores conocidos del VHB empleando RCPc tiempo real mediante el sistema Rotor-Gene 3000 (Corbett Research, Sydney, Australia). Resultados: el sistema utilizado para RCPc tiempo real detecta secuencias de ADN VHB en un amplio rango que puede ser expresado tanto en copias/ml como en UI/ml. Su aplicación permite la clasificación final de los diferentes portadores del VHB, ilustrándose su utilidad en el seguimiento secuencial de aquellos pacientes con HCB en tratamiento. Conclusión: la detección y la medición de secuencias de ADN VHB, en muestras clínicas de suero mediante RCPc en tiempo real, aporta mayor sensibilidad y precisión para definir la historia natural y el estado de replicación viral de los portadores crónicos del VHB antes, durante y posterior al tratamiento.


Introduction: The great need of a reliable, reproducible, specific and highly sensitive method to detect nucleic acids (DNA/RNA), induced the development of real-time quantitative assays based on polymerase chain reaction (real time PCRq). Objective: Description and analysis of a real time PCRq assay for the definition and management of patients with chronic hepatitis B (CHB). Material and Method: Forty serum samples from known HBV carriers were investigated employing real-time PCRq by means of a Rotor-Gene 3000 system (Corbett Research,Sydney,Australia). Results: the system for realtime PCRq detects a wide range of HBV DNA sequences which could be expressed either in copies/mL or in IU/mL .Its application allows the final classification of different HBV carrier status. An illustration of its usefulness in the sequential follow-up of patients on treatment for CHB is made. Conclusion: the detection and measure of HBV DNA sequences in clinical serum samples through real-time PCRq is more sensitive and exact to define the natural history and the status of viral replication in HBV chronic carriers before, during and after treatment.

2.
GEN ; 43(3): 177-81, jul.-sept. 1989. ilus
Article in Spanish | LILACS | ID: lil-105594

ABSTRACT

Una sonda específica para la detección de genomas del VHD fue desarrollada a partir del plásmido recombinante pa-1. La sonda fue marcada mediante un método no isotópico, lo cual permite el almacenaje prolongado de la misma


Subject(s)
Humans , DNA Probes , Hepatitis Delta Virus/genetics , Hepatitis D/diagnosis , Molecular Biology , Electrophoresis, Agar Gel , Genome, Viral/genetics , Hepatitis D/genetics , Hybridization, Genetic , Nucleic Acids , Plasmids/genetics , Recombination, Genetic
SELECTION OF CITATIONS
SEARCH DETAIL